HARDWARE INSTALLATION
26
Step 7. Install the LED Cable (option)
The preferred I/O connector for server backplanes is the inter-
nal SFF-8087 connector. This connector has eight signal pins to
support four SAS/SATA drives and six pins for the SGPIO (Serial
General Purpose Input/Output) side-band signals. The SGPIO bus
is used for efcient LED management and for sensing drive Locate
status. See SFF 8485 for the specication of the SGPIO bus. For
backplane without SGPIO supporting, Please refer to Section 2.4
LED cables for fault/activity LED cable installation.
LED Management: The backplane may contain LEDs to indicate
drive status. Light from the LEDs could be transmitted to the out-
side of the server by using light pipes mounted on the SAS drive
tray. A small microcontroller on the backplane, connected via the
SGPIO bus to a 6Gb/s SAS RAID controller, could control the LEDs.
Activity: blinking 5 times/second and Fault: solid illuminated
Drive Locate Circuitry: The location of a drive may be detected by
sensing the voltage level of one of the pre-charge pins before and
after a drive is installed.
The following signals dene the SGPIO assignments for the Min
SAS 4i internal connector (SFF-8087) in the 6Gb/s SAS RAID con-
troller.
PIN Description PIN Description
SideBand0 SClock (Clock signal) SideBand1 SLoad (Last clock of a bit
stream)
SideBand2 Ground SideBand3 Ground
SideBand4 SDataOut (Serial data
output bit stream)
SideBand5 SDataIn (Serial data input bit
stream)
SideBand6 Reserved SideBand7 Reserved
The SFF-8087 to 4 SATA with sideband cable which follows
SFF-8448 specication. The SFF-8448 sideband signals cable
is reserved for the backplane with header on it.The following
signal denes the sideband connector which can work with Areca
sideband cable on its SFF-8087 to 4 SATA cable.